CANNON 40D 红外改机教程
You will need these tools & supplies to follow the Canon 40D infrared conversion tutorial:
- Our custom glass infrared filter to replace the hotmirror
- Soldering iron and desoldering wick or desoldering gun
- Small philips type screwdriver
- Tweezers
- Canned air
- Lens cleaning solution & tissue
- Grounding strap /w current limit resistor
If you prefer not to risk damage to your camera, have us convert it to infrared for you. It would be best to perform the conversion in a well lit area that is as clean and dust free as possible. Wearing a grounding strap will minimize the chance of zapping your camera with static and most likely rendering it dead.
Remove marked screws.
Remove rubber grip.
Remove marked screws.
Remove marked screws.
Peel up a section of the rubber grip and remove marked screws.
Gently separate the rear cover from the body and disconnect marked cables.
Disconnect the marked cables including the fiber optic cable (blue arrow).
Desolder noise shield as indicated.
Remove the noise shield.
Remove marked screws and disconnect marked cables (red arrows).
Disconnect marked cable and flip over the PCB.
Remove marked screws and flip over the sensor unit.
Disconnect the marked cable.
Remove marked screws.
Remove the grounding form.
Remove the filter retainer.
Remove the dust reduction filter.
Cut the adhesive around the infrared blocking filter to free it from the frame.
Remove the infrared blocking filter.
Install our infrared replacement filter and follow the tutorial in reverse order starting with step 16 to reassemble your camera.